No matter what your building is used for, fire protection and disaster preparedness are critical investments to make—but this endeavor goes beyond installing a sprinkler system and a few alarms. The U.S. Smoke & Fire SD60 Fixed Fabric Draft Curtain is often used in warehouses for smoke zoning and separation and for aircraft hangars as part of NFPA 409 compliance. The system can be free-hanging or mechanically fastened in place to offer comprehensive protection for your needs. Keep reading to learn more.
Fixed-Fabric 1-Hour Smoke Partition
As a smoke and fire curtain supplier, we deliver effective solutions like the SD60 Fixed Fabric Draft Curtain. The SD60 1-Hour Fixed Fabric Draft Curtain is tested to UL 10B, 10C, and 10D as a fire-protective smoke curtain. This curtain is commonly used in industrial environments with high ceilings like airplane hangars and warehouses. The curtain is composed of a tightly woven glass fiber fire-rated fabric material. When placed, it is fixed to the roof deck or other ceiling structure to create a tight seal and provide smoke draft control in large open spaces.
With thorough quality assurance, U.S. Smoke & Fire’s fire curtains stand up to the toughest conditions. Once on-site, our installers will examine supports, blocking, inserts, clips, installation tolerances, clearances, and other conditions that impact the performance of a fixed smoke curtain. In addition, we also offer 37-point electrical and mechanical inspections included in our annual preventative maintenance plans. Read on for technical specifications and images of the SD60 Fixed Fabric Draft Curtain, or contact us now to request more information.
Our Design Options
Call us to learn about our custom design options.
Ceiling Finishes
Wall Finishes
Technical Information About This Product
Additional Product Details for the SD60 Fixed Fabric Curtain
It’s our mission to implement fire protection strategies that meet building codes, create aesthetic appeal, and offer true design flexibility. That includes the performance and testing standards we use to evaluate our products. See the measurements below that we use to provide a practical and efficient solution for effective smoke control and removal.
- 1-hour smoke and fire curtain (UL 10D)
- Fabric area density ≥ 540 g/m² for temperature ≤ 1800°F for a period of 1 hr
- The tensile strength of Panama weave fabric is 10% ≥, with 415g/m² glass cloth
- Tested to UL 10D (1 hour)
- Tested to UL 10B – 20 mins with no hose
- Tested to UL 10C – 20 mins with no hose
- ASTM E84 Test Report
- ASTM 136 Test Report
- California Department of Forestry and Fire
- Protection and Office of the State Fire Marshal Listing
- OSHPD Anchorage Pre-Approval No. OPA-2855-10
- 10D
- NFPA 701
- 20-minute no hose UL 10B
- ASTM E84
- ASTM E136
Stay Connected With Us
Start Planning Your Project
With over two decades of experience designing and installing fire suppression systems, we specialize in creating tailored smoke and fire barriers that enhance the safety of building occupants and the protection of your assets.
Our comprehensive approach optimizes smoke containment, mitigates potential losses, and provides a secure environment in the event of a fire. By implementing draft curtains in accordance with your building’s unique configuration and storage requirements, we can meet these goals without compromising on building design or usable space. Contact us today to request a consultation and receive personalized product recommendations.